beautypg.com

Removing a fortigate-5001a board – Fortinet FortiGate 5001A-SW User Manual

Page 18

background image

FortiGate-5001A Security System Guide

18

01-30000-83456-20081023

Removing a FortiGate-5001A board

Hardware installation

10

Once the board is inserted correctly, fully tighten the retention screws to lock the
FortiGate-5001A board into position in the chassis slot.

Removing a FortiGate-5001A board

The following procedure describes how to correctly use the FortiGate-5001A
mounting components described in

“FortiGate-5001A mounting components” on

page 14

to remove a FortiGate-5001A board from an ATCA chassis slot.

FortiGate-5001A boards are hot swappable. The procedure for removing
a FortiGate-5001A board from a chassis slot is the same whether or not the
chassis is powered on.

To remove a FortiGate-5001A board from a chassis slot

To complete this procedure, you need:

An ATCA chassis with a FortiGate-5001A board installed

An electrostatic discharge (ESD) preventive wrist strap with connection cord

1

Attach the ESD wrist strap to your wrist and to an available ESD socket or wrist
strap terminal.

2

Disconnect all cables from the FortiGate-5001A board, including all network
cables, the console cable, and any USB cables or keys.

Tighten

Retention

Screw

!

Caution: Do not carry the FortiGate-5001A board by holding the handles or retention
screws. When inserting or removing the FortiGate-5001A board from a chassis slot, handle
the board by the front panel. The handles are not designed for carrying the board. If the
handles become bent or damaged the FortiGate-5001A board may not align correctly in the
chassis slot.

!

Caution: FortiGate-5001A boards must be protected from static discharge and physical
shock. Only handle or work with FortiGate-5001A boards at a static-free workstation.
Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when
handling FortiGate-5001A boards.