beautypg.com

FujiFilm 4500N User Manual

Page 111

background image

102

5

.

Adjust the donor so that about 0.8 in. (2 cm) protrudes

from the receiver magazine.

Cut the leading end square. Make sure that the width of

the protruding end does not vary by more than 0.12 in.

(3 mm).

Use care so that the receiver's leading end does not

slip back into the receiver magazine. If it does, it will be

impossible to pull out the receiver.

6

.

Close the left-hand side upper door. Grasp the receiver

leading end and slowly insert the receiver magazine along

the guide.

IMPORTANT:

If the magazine is inserted with the donor's leading end bent,

the machine may multifunction.

NOTE:

Push the receiver magazine all the way in.

7

.

Close the front upper door.

The machine will automatically cut off and discharge

the unusable portion of the receiver's leading end.

IMPORTANT:

Do not open the door during the receiver discharge

process. Receiver jamming may occur.

Do not turn the power switch to OFF ( ) or disconnect

the power plug during the receiver discharge process.

Receiver jamming may occur.

6.5 Jamming at Location "6"

0.8 in.
(2 cm)