Performing routine maintenance
41
4.
Loosen the two screws in the lamp cover
1
and remove the cover
2
.
5.
Remove the two screws
3
from the lamp module, raise the handle
4
, and lift out the
module
5
.
6.
Insert the new lamp module into the projector and tighten the two screws.
7.
Replace the lamp cover and tighten the two screws.
8.
Turn on the projector. If the lamp does not turn on after the warm-up period, try reinstalling
the lamp.
9.
Press enter, go to Setup > Advanced setup > Reset lamp hours, and press enter.