WATER SUPPLY-CSG

The Combi-Steamer should only be connected to a cold water supply which meets the quality requirements by the EPA on
drinking water. Soft water must be at least 5 or 6 grains.

The recommended water supply pressure is 44 psi, but 22 to 87 psi will work.

The water connection is done on a 3/4” NPT thread fitting, and a manual shut-off valve must be installed between the main
cold water supply and the units supply line.

NOTE: A check valve is built into the unit to prevent backflow.

DRAIN CONNECTION-CSG

The Combi-Steamer is to be installed to comply with the applicable Federal, State, or local plumbing codes.

The unit has an integrated vented drain system which acts as a reverse flow check valve, so it may be connected directly
with a P-trap to the drain system.

Should the water pressure exceed 87 psi, a pressure regulator must be installed into the supply line or damage to
the unit could result.

A minimum water conductivity of 20 micro Siemens is required for proper operation, If below this figure the
steam generator will over-fill.

The drain must have a constant slope and a diameter of 2 inches over its entire length to ensure sufficient
discharge during Auto Flush from the steam generator, which is 3/4 quarts per second.

The drain must be steam temperature resistant pipe, which average drain temperature is 150°F (65°C). No hose
should be used.

Both water and gas connections are 3/4” NPT fittings. Be sure to connect to proper pipe. Check label on unit for each.