Table 47, Lues. see, Table 49 – HP 2/8q Fibre Channel User Manual
Page 134

Command Line Interface
134
HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
Table 47: Port threshold alarm configuration default settings
Parameter
Default setting
ThresholdMonitoringEnabled
False
CRCErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
25
1
10
DecodeErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
200
0
10
LoginMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
5
1
10
LogoutMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
5
1
10
LOSMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
100
5
10
Table 48: Zoning configuration default settings
Parameter
Default setting
InteropAutoSave
True (not supported)
Default Visibility
All
Table 49: SNMP configuration default settings
Parameter
Default setting
SNMPEnabled
True
Contact
Location
Description
HP StorageWorks 2/8q FC Switch
Trap [1-5] Address
Trap 1: 10.0.0.254; Traps 2–5: 0.0.0.0
Trap [1-5] Port
162
Trap [1-5] Severity
Warning
Trap [1-5] Version
2
Trap [1-5] Enabled
False