beautypg.com

Heat & Glo Fireplace LUX60 User Manual

Page 48

background image

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

48

1 1/2 in. MAXIMUM

Air Flow

Steel Stud Assy

1/2 in.
Cement Board

Wood Framing

Sheetrock

Figure 14.3 1/2 in. Sheetrock plus Wall Finishing to 1 in.

B. Additional Decorative Finishing up to 1 in.
(25 mm) Thick

If an additional decorative facing is to be used (i.e. tile,
marble) the front edge of the appliance must be 1/2 in.
(13 mm) plus the thickness of the facing material (up to
1 in./25 mm thick) past the edge of the framing to achieve
a fl ush fi t with the SSF-LUX-BK Surround Kit. See Figure
14.3.

Steel Stud Assy

1/2 in. (13 mm)
Cement Board

Wood Framing

Sheetrock

Top Rock
Template

1/2 in. (13 mm)

Air Flow

SSF-LUX-BK

(shown for

reference only)

1 in. (25 mm)

air gap

Figure 14.4 1/2 in. Sheetrock plus Wall Finishing over 1 in.

C. Additional Decorative Finishing over 1 in.
(25 mm) Thick

If the additional decorative facing is to be used is over
1 in./25 mm thick (i.e. rock, brick, etc.) the front edge of
the appliance must be 1/2 in. (12 mm) past the edge of
the framing. The LUX60-TMPLT Rock Template must be
used to allow air fl ow through the SSF-LUX60 Surround
Kit. See Figure 14.4.

Use the instructions included with the template for instal-
lation.

WARNING! Risk of Fire! DO NOT restrict the 1 in. air
gap with any facing material!