Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification

369

B

43

00

Message Error

152A Message reject error (SCSI only)

152C Message parity error rcvd when no message sent by target (SCSI only)

B

44

00

Internal Target Failure

152D Buffer CRC error on read

152E Internal target failure - Host Interface

154A Xfer Ready credit exceeded (FC-AL only)

154B Xfer length error (FC-AL only)

1568 End-to-End Data Protection Guard check

1569 End-to-End Data Protection Application Tag check

156A End-to-End Data Reference Tag check

156B ECC error in DRAM customer data area

156C Uncorrectable DRAM ECC error

1570 Host interface CRC error

F645 Unrecovered Channel coarse tune timeout

F75C Internal media access timeout

F761 Read/write command timeout

F772 DASH starting timeout

F773 ID table timeout

F774 Servo timeout

F775 Buffers timeout

F776 DASH done timeout

F777 DASH unknown timeout

F77A Unrecovered Channel SBW timeout

F77D Recovery timeout

F7B1 Overall command timeout

F7D0 Pre-load timeout

B

45

00

Select or Reselect Failure

152F Selection reselection error (SCSI only)

B

47

00

SCSI Parity Error

1530 Message parity error - initiator (SCSI only)

1531 Message parity error - target (SCSI only)

B

47

03

Information Unit iuCRC Error Detected

1543 IU SCSI CRC error

B

48

00

Initiator Detected Error Message Received

1532 Initiator detected error message received (SCSI only)

B

49

00

Invalid Message Error