Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification

155

Table 133: Log Sense Page 10, Extended Segment Number

Timestamp This field contains the total accumulated power-on hours of the Target at the time the self-test completed.

LBA of first failure This field contains the LBA of the first logical block address where a self-test error occurred. If no

errors occurred during the self-test or the error is not related to a LBA then the field will be FFFFFFFFFFFFFFFFh.

Sense Key, Additional Sense Code and Additional Sense Code Qualifier These fields will contain the additional

information relating to the error or exception conditions during self-test.

See Section 19.40 “SEND DIAGNOSTIC (1D)” on page 262, for detailed listing of operations carried out by SEND DIAG-
NOSTIC command and Power on Diagnostics.

Extended

Segment

Number

Short Self-Test

Extended Self-Test

1h

Drive Ready Test

2h

Drive Diagnostics

3h

SMART

4h

Low Level Format check

5h

Physical Head Check

6h

Random Verify

7h

- Verify First 300 MB

- Verify Last 100 MB

Verify all LBAs

8h

Recheck SMART