Over The Range Convection Microwave Oven / Installation Manual

8 / 63 EN

4

External exhaust

4.1 Installing hood exhaust

C

Read these instructions only if you

plan to vent your exhaust to the out-

side. If you plan to recirculate the air

back into the room, proceed to title 5

4.1.1 Outside top exhaust

(example only)

The following chart describes an example of one

possible ductwork installation.

Duct pieces

Equivalent

Length

x

Number

used

=

Equivalent

Length

Roof Cap

24 Ft. (7.3 m)

x

(1)

= 24 Ft. (7.3 m)

12 Ft. (3.6 m)

Straight Duct

(6”/15.2 cm

Round)

12 Ft. (3.6 m)

x

(1)

= 12 Ft. (3.6 m)

Rectangular-to-

Round

Transition Adap-

tor*

5 Ft. (1.5 m)

x

(1)

= 5 Ft. (1.5 m)

Equivalent lengths of duct pieces are based on actual tests

and reflect requirements for good venting performance

with any vent hood.

Total Length

= 41 Ft. (12.5 m)

C

If a rectangular-to-round transition

adaptor is used, the bottom corners

of the damper will have to be cut to

fit, using the tin snips, in order to al-

low free movement of the damper.