beautypg.com

4external exhaust, 10 / 63 en, 4 maximum duct length – Beko 30 Inch Over the Range Convection Microwave Installation Guide User Manual

Page 10: 5 elbows, transitions, wall and roof caps, etc

background image

Over The Range Convection Microwave Oven / Installation Manual

10 / 63 EN

4

External exhaust

4.1.4 Maximum duct length

For satisfactory air movement, the total duct

length of 3

1⁄4

” x 10” (8.2 x 25.4 cm) rectangular or

6” (15.2 cm) diameter round duct should not ex-

ceed 120 equivalent feet (36.5 m).

4.1.5 Elbows, transitions, wall

and roof caps, etc.,

Present additional resistance to airflow and are

equivalent to a section of straight duct which is

longer than their actual physical size. When cal-

culating the total duct length, add the equivalent

lengths of all transitions and adaptors plus the

length of all straight duct sections. The chart be-

low shows you how to calculate total equivalent

ductwork length using the approximate feet of

equivalent length of some typical ducts.

Duct pieces

Equivalent

Length

x

Number

used

=

Equivalent

Length

Rectangular-to-Round

Transition Adaptor*

5 Ft. (1.5 m)

x

( )

= Ft. or m

Wall Cap

40 Ft. (12.2 m) x

( )

= Ft. or m

90° Elbow

10 Ft. (3 m)

x

( )

= Ft. or m

45° Elbow

45° Elbow

x

( )

= Ft. or m

90° Elbow

25 Ft. (7.6 m)

x

( )

= Ft. or m