Using LANVIEW
SecureStack A2 PoE Installation Guide 4-5
RPS
Off
The RPS LED remains off
regardless if the RPS is
attached or not. The LED being
in its off state is not an
indication that the RPS is not
functioning properly and won’t
supply power in the event of an
AC power supply failure.
See Amber state below.
None.
Amber
Solid.The switch internal
power supply failed, and the
RPS is providing the proper
power to the switch.
1. Ensure that the AC power cord is
plugged in correctly and that there is
power at the AC power source.
2. Replace the power cord with a known
good one.
3. If the problem persists, contact
Enterasys Networks for technical
support.
Link
Activity
Off
1. No link - no connection.
2. Remote device powered off.
3. Port in standby.
4. Cable is bad.
None.
Power on remote device.
Use CLI to enable port.
Replace UTP cable with a known good
one.
Green
Solid. Port is linked, but the
interface is not receiving any
traffic.
None.
Blinking. Port is linked and
traffic is being received or
transmitted by the interface.
None.
Table 4-1 LANVIEW LEDs (continued)
LED
Color
State
Recommended Action