Rack mounting the switch, Guidelines for rackmount installation, Attaching brackets and installing in rack – Enterasys Networks Enterasys SecureStack A2 A2H124-48P User Manual
Page 36: Rack mounting the switch -6, Attaching the rackmount brackets -6, Ба б а
Rack Mounting the Switch
3-6 Hardware Installation
Rack Mounting the Switch
To install the switch in a 19‐inch rack, you need:
•
Two rackmount brackets and mounting screws (rackmount kit) shipped with the
switch.
•
Four user‐supplied screws to attach the switch to a standard 19‐inch rack.
Guidelines for Rackmount Installation
The installation site must be within reach of the network cabling and meet the
requirements listed below:
•
Appropriate grounded power receptacles must be located within 152 cm (5 ft) of the
location.
•
A temperature of between 0°C (32°F) and 40°C (104°F) must be maintained at the
installation site with fluctuations of less than 10°C (18°F) per hour.
Attaching Brackets and Installing in Rack
Proceed as follows to install the switch into a 19‐inch rack:
1.
Attach the rackmount brackets to the switch, as shown in
, using the eight
M3x6 mm flathead screws shipped with the switch.
Figure 3-3 Attaching the Rackmount Brackets
Note: To ensure proper ventilation and prevent overheating, leave a minimum clearance
space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch.
Warning: Before rack-mounting the switch, ensure that the rack can support it without
compromising stability. Otherwise, personal injury and/or equipment damage may result.
Advertencia: Antes de montar el equipo en el rack, asegurarse que el rack puede
soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o
del equipo puede ocurrir.
Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.
1 Rackmount brackets
2 M3x6 mm flathead screws
Б
А
Б
А
1
2
11
12
13
14
23
24
Console
25
26
27
28
25/Up
26/Down
Stack
27
28
1
3
5
7
9
11 13 15 17 19 21 23
2
4
6
8
10 12 14 16 18 20 22 24
CPU
RPS
MGR
A2H124-24P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24