Removing the mini-gbic, Removing the mini-gbic -26, Mini-gbic with lc connector -26 – Enterasys Networks Enterasys SecureStack A2 A2H124-48P User Manual
Page 56: Figure 3‐19, Вб а г
Installing Optional Mini-GBICs
3-26 Hardware Installation
Figure 3-19 Mini-GBIC with LC Connector
Removing the Mini-GBIC
1 SFP Slot
3 Release tab
2 Mini-GBIC
(MGBIC-LC01,-LC03, -LC09, MGBIC-08)
4 Link/Activity LED
27
28
A2H124-24P
25
26
27
28
25/Up
26/Do
wn
Stac
k
В
Б
А
Г
Caution: Do NOT remove a Mini-GBIC from a slot without releasing the locking tab
located under the front bottom end of the Mini-GBIC. This can damage the Mini-GBIC.
The Mini-GBIC and its host switch are sensitive to static discharges. Use an antistatic wrist
strap and observe all static precautions during this procedure. Failure to do so could result
in damaging the Mini-GBIC or host switch. Always leave the Mini-GBIC in the antistatic
bag or an equivalent antistatic container when not installed.
Precaución: NO quite el Mini-GBIC de la ranura sin antes abrir la traba ubicada en la
parte frontal del Mini-GBIC.
Si lo hace, puede dañar el Mini-GBIC, puesto que es muy sensible a las descargas de
electricidad estática, al igual que el dispositivo host. Utilice la pulsera antiestática y tome
todas las precauciones necesarias durante este procedimiento. Si no lo hace, pude dañar
el Mini-GBIC o el dispositivo host. Mientras no esté instalado, mantenga el Mini-GBIC en
su bolsa antiestática o en cualquier otro recipiente antiestático.