Connecting Two OCTA-CAPTURE Units
If you connect two OCTA-CAPTURE units, you’ll be able to use them as a 24-in/20-out audio interface
with ASIO on Windows or with Core Audio on Mac OS X.
In order to connect two OCTA-CAPTURE units and use them, you must turn on the VS EXPAND
setting of the second unit, and set both units to digitally synchronize at the same sampling
frequency.
*
A maximum of two OCTA-CAPTURE units can be connected simultaneously .
Before you start making settings, disconnect both OCTA-CAPTURE units from the computer and turn
off their power.
First unit (OCTA-CAPTURE)
Second unit (OCTA-CAPTURE EXP)
COAXIAL OUT (9/10)
COAXIAL IN (9/10)
Coaxial Cable
1
4
2 3
5
6
6
9
7
7
VS EXPAND: OFF
DIGITAL: AUTO
SAMPLE FREQ:
Same settings as second unit
VS EXPAND: ON
DIGITAL: AUTO
8
1.
Switch on the power to the second OCTA-CAPTURE unit .
The second OCTA-CAPTURE unit will be the timing master.
2.
Specify the sampling frequency (p . 68) .
*
When using two units, they cannot be used with the 192 kHz setting .