DNPM ♦ ProLinx Gateway
Reference
DNP 3.0 Master
Driver Manual
Page 42 of 56
ProSoft Technology, Inc.
September 30, 2009
OBJECT REQUEST
RESPONSE
Obj Var Description
Func
Codes
Qual
Codes
(hex)
Func
Codes
Qual
Codes
(hex)
Data
Size
(bits)
NOTES
8
16-Bit Frozen Delta
Counter Event With
Time
72
30 0
Analog Input: All
Variations
1 06
16
Master will generate this variation
1
32-Bit Analog Input 1
06 129,
130
00, 01
40
Master will generate and process this
variation. Data returned will be least
significant 16 bits. Status flag will be
discarded.
2
16-Bit Analog Input 1
06 129,
130
00, 01
24
Master will generate and process this
variation
3
32-Bit Analog Input
Without Flag
1
06 129,
130
00, 01
32
Master will generate and process this
variation. Data returned will be least
significant 16 bits.
4
16-Bit Analog Input
Without Flag
1
06 129,
130
00, 01
16
Master will generate and process this
variation
31 0 Frozen
Analog
Input: All Variations
1 32-Bit
Frozen
Analog Input
40
2
16-Bit Frozen
Analog Input
24
3
32-Bit Frozen
Analog Input With
Time To Freeze
88
4
16-Bit Frozen
Analog Input With
Time To Freeze
72
5
32-Bit Frozen
Analog Input
Without Flag
32
6
16-Bit Frozen
Analog Input
Without Flag
16
32 0 Analog
Change
Event: All
Variations
1
06, 07, 08
24
Master will generate this variation
1 32-Bit
Analog
Change Event
Without Time
1
06, 07, 08 129,
130
17, 28
40
Master will generate and process this
variation. Data returned will be least
significant 16 bits. Status flag will be
discarded.
2 16-Bit
Analog
Change Event
Without Time
1
06, 07, 08 129,
130
17, 28
24
Master will generate and process this
variation. Status flags are discarded.