User’s Manual of WGSD-10020 Series
Figure 4-16-2:
PoE Configuration Screenshot
The page includes the following fields:
Object
Description
System PoE Admin
Mode
Allows user to enable or disable PoE function. It will cause all of PoE ports to
supply or not supply power.
PoE Temperature
Protection
Allows user to enable or disable PoE Temperature Protection.
PoE Management
Mode
There are Six modes for configuring how the ports/PDs may reserve power and
when to shut down ports.
Class-Consumption mode:
System offers PoE power according to PD real
power consumption.
Class-Reserved-Power mode:
System reserves PoE power to PD
according to PoE class level.
Allocation-Consumption mode:
System offers PoE power according to PD
real power consumption.
Allocation-Reserved-Power mode:
Users allow to assign how much PoE
power for per port and system will reserve PoE power to PD.
LLDP-Consumption mode:
System offers PoE power according to PD real
power consumption.
LLDP-Reserved-Power mode:
System reserves PoE power to PD
according to LLDP configuration.
Power Supply Budget
[W]
Set limit value of the total PoE port provided power to the PDs.
WGSD-10020HP
available maximum value is 150watts.
Temperature
Threshold
Allows setting over temperature protection threshold value. It system
temperature was over it then system lower total PoE power budget automatically.
PoE Usage Threshold
Allows setting how much PoE power budget could be limited.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation. However, to improve power management
at the PSE, the PD provides a signature about Class level.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.