beautypg.com

19 digital input/output – PLANET MGSW-24160F User Manual

Page 74

background image

User’s Manual of MGSW-24160F

4.2.19 Digital input/output

Digital Input

allows user can log external device (such as industrial cooler) dead or alive or something else, system will logs a

user cistomize message into system log, syslog, issue SNMP trap or issue an alarm E-mail.

Digital Output

allows user to monitor the switc port and power , and let system issues a high or low signal to an external device

(such as alarm) when the monitor port or power has been failed. The Configuration screen in

Figure 4-2-26

appears.

Figure 4-2-26

Windows File Selection Menu Popup

The page includes the following fields:

Object

Description

Enable

Checks the Enable checkbox will enable Digital Input / output function.

Unchecks the Enable checkbox will disable Digital input / output function.

Condition

As Digital Input:

Allows user selecting to High to Low or Low to High. This is means a signal

received by system is from High to Low or From Low to High, it will trigger an

action that logs a customize message or issue the message from the switch.

As Digital Output:

Allows user selecting to High to Low or Low to High. This is means

that when

the switch has power failed or port failed then system will issue a High

or Low signal to an external device (such as an alarm).

74