Di_en – PLANET MGSW-24160F User Manual
Page 493

User’s Manual of MGSW-24160F
Syntax:
Di_desc [first|second] [
Parameters:
: Digital input/output 1
: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
: Digital input1/2 described string. Use 'clear' or "" to clear the string In CLI, no blank or space characters
are permitted as part of a contact.
Example:
Set digital input alarm message.
SWITCH/>dido di_desc first "window was opened!"
Di_en
Description:
Set or show the system digital input1/2.
Syntax:
di_desc [first|second] [
Parameters:
: Digital input/output 1
: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
: Enable digital input1/2 function
: Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
: Trigger -> high to low
: Trigger -> low to high
(default: Set or show digital input/output 1/2 trigger)
Example:
Enable digital input function and set trigger condition.
SWITCH/>dido di_en first enable hightolow
493