User’s Manual of MGSW-24160F

to the similar bridge setting, the port Edge status doesn’t affect this setting.

A port entering error-disabled state due to this setting is subject to the bridge Port

Error Recovery setting as well.

Point2Point

Controls whether the port connects to a point-to-point LAN rather than a shared

medium. This can be automatically determined, or forced either true or false.

Transition to the forward state is faster for point-to-point LANs than for shared

media.

(This applies to physical ports only. Aggregations are always forced Point2Point).

Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.

By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost

according to the values shown below. Path cost “0” is used to indicate auto-configuration mode. When the short path cost

method is selected and the default path cost recommended by the IEEE 8021w standard exceeds 65,535, the default is set to

65,535.

Port Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

50-600

200,000-20,000,000

Fast Ethernet

10-60

20,000-2,000,000

Gigabit Ethernet

3-10

2,000-200,000

Table 4-7-1

Recommended STP Path Cost Range

Port Type

Link Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Ethernet

Half Duplex

Full Duplex

Trunk

100

95

90

2,000,000

1,999,999

1,000,000

Fast Ethernet

Half Duplex

Full Duplex

Trunk

19

18

15

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

4

3

10,000

5,000

Table 4-7-2

Recommended STP Path Costs

Port Type

Link Type

IEEE 802.1w-2001

Ethernet

Half Duplex

Full Duplex

Trunk

2,000,000

1,000,000

500,000