Fault_act – PLANET MGSW-24160F User Manual
Page 496

User’s Manual of MGSW-24160F
: Digital input/output 1
: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
: DC power 1
: DC power 2
: AC power
(default: Set or show digital output/fault alarm 1/2 power_fail)
: Enable digital input1/2 function
: Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable power alarm configuration.
SWITCH/>dido do_pwr_alr first dc1 enable
SWITCH/>dido do_pwr_alr first dc2 enable
SWITCH/>dido do_pwr_alr first ac enable
fault_act
Description:
Set or show the system fault alarm action.
Syntax:
dido fault_act [port|power] [enable|disable]
Parameters:
: port fail
: power fail
(default: Set or show digital output/fault alarm 1/2 action)
: Enable digital input1/2 function
: Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable power alarm configuration.
SWITCH/>dido fault_act port enable
SWITCH/>dido fault_act power enable
496