beautypg.com

Fault_en, Fault_port_alr, Fault_pwr_alr – PLANET MGSW-24160F User Manual

Page 497

background image

User’s Manual of MGSW-24160F

fault_en

Description:

Set or show the system fault alarm.

Syntax:

dido fault_en [enable|disable]

Parameters:

: Enable digital input1/2 function

: Disable digital input1/2 function

(default: Set or show digital input/output/fault alarm 1/2 status)

Example:

Enable power alarm configuration.

SWITCH/>dido fault_en enable

fault_port_alr

Description:

Set or show the system fault alarm of port alarm.

Syntax:

dido fault_port_alr []

Parameters:

: Port list or 'all', default: All ports

Example:

Enable power alarm configuration.

SWITCH/>dido fault_port_alr all

SWITCH/>dido fault_port_alr 1,3,5

SWITCH/>dido fault_port_alr 1-10

fault_pwr_alr

Description:

Set or show the system fault alarm of power alarm.

Syntax:

dido fault_pwr_alr [dc1|dc2|ac] [enable|disable]

497