beautypg.com

PLANET GSW-1602SF User Manual

Page 125

background image

User’s Manual of GSW-1602SF / GSW-2404SF

Object

Description

Port Description

Optional TLV: When checked the "Port Description" is included in LLDP information

transmitted.

System Name

Optional TLV: When checked the "System Name" is included in LLDP information

transmitted.

System Description

Optional TLV: When checked the "System Description" is included in LLDP information

transmitted.

System Capabilities

Optional TLV: When checked the "System Capability" is included in LLDP information

transmitted.

The system capabilities identify the primary function(s) of the system and whether or not

these primary functions are enabled. The information advertised by this TLV is described in

IEEE 802.1AB.

Management Address

Optional TLV: When checked the "Management Address" is included in LLDP information

transmitted.

The management address protocol packet includes the IPv4 address of the switch. If no

management address is available, the address should be the MAC address for the CPU or

for the port sending this advertisement. The management address TLV may also include

information about the specific interface associated with this address, and an object identifier

indicating the type of hardware component or protocol entity associated with this address.

Table 4-39

Description of the Transmitted TLVs Parameters

„

Parameters

„

The Parameters includes the following items: Table 4-40 Description of the Parameters.

Object

Description

Tx Interval

The Web Smart Gigabit Switch is periodically transmitting LLDP frames to its

neighbors for having the network discovery information up-to-date. The interval

between each LLDP frame is determined by the Tx Interval value. Valid values

are restricted to 5 - 32768 seconds.

Default: 30 seconds

This attribute must comply with the following rule:

(Transmission Interval * Hold Time Multiplier) ≤65536, and Transmission Interval

>= (4 * Delay Interval)

Tx Hold

Each LLDP frame contains information about how long the information in the

LLDP frame shall be considered valid. The LLDP information valid period is set to

-119-