beautypg.com

2 cable diagnostics – PLANET GSW-1602SF User Manual

Page 121

background image

User’s Manual of GSW-1602SF / GSW-2404SF

The Ping Parameters includes the following fields: Table 4-36 Description of the Ping Parameters.

Item

Description

Target IP Address

Enter the IP address of the station you want the Web Smart Gigabit Switch to ping. The initial
value is blank. The IP Address you enter is not retained across a power cycle.

Count

Number of echo requests to send

Time Out (in secs)

Timeout in milliseconds to wait for each reply.

Button

Apply

Press this button for save current configuration of Web Smart Gigabit Switch.

Table 4-36

Description of the Ping Parameters

After field the parameter and press “Apply” to execute the Ping function. The Ping result shows at the next table. As the

screen in

Figure 4-84

appears.

Figure 4-84

Ping Result screen

Be sure the target IP Address is within the same network subnet of the Web Smart Gigabit Switch, or
you had setup the correct gateway IP address.

4.13.2 Cable Diagnostics

The Cable Diagnostics page contains fields for performing tests on copper cables. These functions have the ability to

identify the cable length and operating conditions, and to isolate a variety of common faults that can occur on the Cat5

twisted-pair cabling. There might be two statuses as follow:

„

If the link is established on the twisted-pair interface in 1000BASE-T mode, the Cable Diagnostics can run without

disruption of the link or of any data transfer.

„

If the link is established in 100BASE-TX or 10BASE-T, the Cable Diagnostics cause the link to drop while the

diagnostics are running.

After the diagnostics are finished, the link is reestablished. And the following functions are available.

• Coupling between cable pairs.

-115-