beautypg.com

Figure 5-9. calibration window, Figure 5-10. limit model window, Calibration window -12 – KEPCO KLR Series Developers Guide User Manual

Page 74: 10 limit model window -12

background image

5-12

KLR-DEV 060713

The Calibrate button opens the Calibration Window (Figure 5-9), and is used to recalibrate the
unit (see Section 4 of the KLR User Manual). This button is disabled for master/slave configura-
tions; units must be configured for Standalone to be calibrated.

FIGURE 5-9. CALIBRATION WINDOW

The ABOUT button displays the model, serial number, firmware version number and driver ver-
sion number. Click OK to close the window

The Limit Model button opens the Limit Model window (Figure 5-10) which displays the present
limit model settings; these limits may be changed by the user. To change these limits the Cali-
bration Password (see KLR User Manual) must be entered. Once either limit is altered, the out-
put is automatically disabled and the previous settings for voltage and current are lost.

FIGURE 5-10. LIMIT MODEL WINDOW

The Front Panel button allows all front panel controls to be locked during remote operation.
When the front panel is locked the button color changes from green to red.