beautypg.com

4 using the driver functions, 1 kepcodcpwr configure voltage level.vi, 1 connector panel – KEPCO KLR Series Developers Guide User Manual

Page 45: 2 controls and indicators, Using the driver functions -3, Epco, Connector panel -3, Controls and indicators -3

background image

KLR-DEV 060713

4-3

4.4

USING THE DRIVER FUNCTIONS

The interactive example uses various driver functions of the LabView G driver. The following two
paragraphs details the inputs and outputs of two of typical VI’s used in the interactive example:
KepcoDCPwr Configure Voltage Level.vi (PAR. 4.4.1) and KepcoDCPwr Measure [MSR].vi
(PAR. 4.4.2). An overall block is provided for each function which shows inputs and outputs, fol-
lowed by detailed descriptions of inputs and outputs. A detailed block diagram with associated
text is also provided to show how the function is implemented.

4.4.1

KepcoDCPwr Configure Voltage Level.vi

This VI configures the DC voltage level the power supply is expected to generate.

4.4.1.1

CONNECTOR PANEL

FIGURE 4-1. KepcoDCPwr Configure Voltage Level.vi CONNECTOR PANEL

4.4.1.2

CONTROLS AND INDICATORS

See Table 4-2.

KepcoDCPWR Clear All Lists

Clears the list if not executing.

KepcoDCPWR Configure List

Loads a specific list from an array of numbers.

KepcoDCPWR Configure List Count

Initializes the list count variable

Trigger Functions

KepcoDCPWR Configure Triggered Current Level

Establishes the current level upon receipt of a valid trigger

KepcoDCPWR Configure Triggered Voltage Level

Establishes the voltage level upon receipt of a valid trigger

KepcoDCPWR Configure Triggered Source

Establishes the source for a trigger and arms the trigger sys-
tem.

KepcoDCPWR initiate[TRG]

Issue a software trigger to the KLR.

KepcoDCPWR Abort [TRG]

Clears the trigger system.

Error and status reporting

KepcoDCPWR Error-Query

Provides entry from the error queue of the power supply.

TABLE 4-1. KLR LABVIEW G DRIVER FUNCTIONS (CONTINUED)

Function Name

Purpose