beautypg.com

KEPCO KLR Series Developers Guide User Manual

Page 128

background image

B-26

KLR-DEV 060713

-123,”Exponent too large”

Command Error bit 5 Exponent E+3 or greater is invalid.

-141,”Invalid character data”

Command Error bit 5 For example OUTP OFD or OUTP STOP instead of OUTP OFF.

-150,”String data error”

Command Error bit 5

Invalid characters were detected in numeric entry.For example E.1
instead of E+1 or 4d3 instead of 4.3.

-203,”Command protected”

Execution Error bit 4 Password must be CENabled.

-207,”Location is empty”

Execution Error bit 4 Recalled location has no data stored.

-211,”Trigger Ignored”

Execution Error bit 4 Trigger ignored because output is off.

-213,”INIT ignored”

Execution Error bit 4

Request for measurement ignored because another measurement
already in progress.

-221,”Settings conflict”

Execution Error bit 4

E.g. , Invalid password from syst:pass:cen command. or Calibration
state not enabled but CALibrate command received.

-222,“Current, Voltage or Data out of
range”

Execution Error bit 4

Value (current or voltage) exceeds power supply rating or (data)
exceeds acceptable command parameters.

-223,”Data format error”

Execution Error bit 4 Multiple decimal points, Multiple exponents, etc.

-224,“Illegal parameter value”

Execution Error bit 4 For example, OUTP 2 instead of OUTP 1.

-226,“Lists not same length”

Execution Error bit 4

During a LIST command, number of DWEL list entries was not equal
to 1 and did not match number of LIST:VOLT or LIST:CURR entries.

-280,“Program Error“

Execution Error bit 4 LIST execution error, e.g., program already running.

-301,”Value bigger than limit”

Device Error bit 3

E.g., requesting a voltage or current that exceeds the limit.

-302, “Mode changed to Voltage”
-302, “Mode changed to Current”

Device Error bit 3

Power supply operating in current mode changed to voltage mode.
Power supply operating in voltage mode changed to current mode.

-303, “Output Lead Fault”

Device Error bit 3

Excessive voltage drop detected between power and sense lead.

-304, “Current Protection Fault”

Device Error bit 3

Current exceeded programmed protection value.

-305, “Voltage Protection Fault”

Device Error bit 3

Voltage exceeded programmed protection value.

-306, “Over Temperature Shutdown”

Device Error bit 3

Internal temperature exceeded thermal protection limit.

-307, “Power Loss Fault”

Device Error bit 3

Source power loss occurred.

-308, “Fan Fault”

Device Error bit 3

Fan fault detected.

-310,”System Failure”

Device Error bit 3

Program checksum incorrect.

-311,”Memory Error”

Device Error bit 3

E.g., power-up NV RAM error, or CALibrate:STORe error.

-313,”Calibration Memory Lost”

Device Error bit 3

No valid calibration found.

-314,”Save/recall memory error”

Device Error bit 3

Using cell other than 1 - 40 for SAV and RCL.

-315,”Configuration Memory Error”

Device Error bit 3

Configuration Memory Error.

-330,”Self Test Failed”

Device Error bit 3

Self test failed.

-340,”Calibration Failure”

Device Error bit 3

Unable to perform auto calibration.

-341,”Non Volatile Mem. CRC error”

Device Error bit 3

Power supply constants may be corrupted; recalibration may be nec-
essary.

-350,”Queue Overflow”

Device Error bit 3

More than 15 errors are in queue. Error queue was full, error events
have been lost.

-410,”Query interrupted”

Query Error bit 2

New command sent before data from previous query read. Previous
query data lost.

-430,”Query Deadlocked”

Query Error bit 2

Over 255 characters received in single input string.

TABLE B-5. ERROR MESSAGES (CONTINUED)

ERROR MESSAGE

ESR ERROR BIT SET

(SEE PAR. A.5)

EXPLANATION