B.99 SYSTem:PASSword:CENable COMMAND

SYST:PASS:CEN

Syntax:

Short Form: SYST:PASS:CEN

Long Form: SYSTem:PASSword:CENable

Description: Sets the password enable state if the value matches the current password. This command allows

other commands such as the CAL commands to operate. Table B-4 shows the factory default calibra-
tionpasswords.

B.100 SYSTem:PASSword:CDISable COMMAND

SYST:PASS:CDIS

Syntax:

Short Form: SYST:PASS:CDIS

Long Form: SYSTem:PASSword:CDISable

Description: Clears the password enable state if the value matches the current password.

B.101 SYSTem:PASSword:NEW COMMAND

SYST:PASS:NEW

Syntax:

Short Form: SYST:PASS:NEW ,
Long Form: SYSTem:PASSword:NEW ,

Description: Establishes new password. The old (current) password is checked, then replaced by the new pass-

word.

B.102 SYSTem:PASSword[:CENable]:STATe? QUERY

SYST:PASS:STAT?

Syntax:

Short Form: SYST:PASS[:CEN]:STAT?

Long Form: SYSTem:PASSword[:CENable]:STATe?

Return Value: 0 or 1 (1 = enabled, 0 = disabled)

Description: Returns a 1 if the password state is enabled or a 0 if it is disabled.

B.103 SYSTem:SECurity:IMMediate COMMAND

SYST:SEC:IMM

Syntax:

Short Form: SYST:SEC:IMM

Long Form: SYSTem:SECurity:IMMediate

Description: Initializes all NVRAM variable to factory defaults. This includes clearing all *SAV/*RCL locations,

returning all relay functions to factory default settings, and setting Quick Boot feature to OFF. This
command does not affect limit model and corresponding protection limits, last setting recall register or
present operating conditions. NOTE: System password must be enabled prior to issuing this com-
mand (see PAR. B.99).

B.104 SYSTem:SET COMMAND

SYST:SET

Syntax:

Short Form: SYSTem:SET {CM0 | DC0 | DC1 | LF0 | LF1 | KL0 | KL1 | L250 | M40 | SCP}
Long Form: SYSTem:SET {CM0 | DC0 | DC1 | LF0 | LF1 | KL0 | KL1 | L250 | M40 | SCP}

Description: Establishes Device Clear, Line Feed, and Reset functions. Sending SYST:SEC:IMM sets LF1,

DC0, and RO0 (as if CM0 was sent). Sending SYST:SET CM1 sets the KLR to operate in compatible
mode and have all GPIB functions compatible with software version 2.9 and lower units. Sending
SYST:SET CM0 sets the unit to be fully SCPI 1997 compliant.

CM0

Establishes DC0, LF0, conditions described below (SCPI 1997 Standard compliance).

DC0

Device Clear functions per IEEE 488.2 Standard. (No effect on the device (power supply),
only clears internal status registers.)

LF0

Line Feed not provided upon empty buffer condition (no effect when access is via LAN
interface).

DC1

Device Clear functions identical to *RST (Output set to 0V, voltage mode and output set to
OFF except if RO1 (see below) is set.)

LF1

Line Feed provided if buffer is empty and a read is performed. (no effect when access is
via LAN interface).

TABLE B-4. FACTORY DEFAULT CALIBRATION PASSWORDS

MODEL

(** Standard or E-Series)

PASSWORD

KLR 20-120-**

2012

KLR 40-60-**

3660

KLR 75-32-**

7533

KLR 150-16-**

1516

KLR 300-8-**

3008