B.84 SYSTem:COMMunication:SERial:ECHO COMMAND
SYST:COMM:SER:ECHO
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:ECHO {1 | 0} (1 = on, enabled, 0 = off, disabled)
Long Form: SYSTem:COMMunication:SERial:ECHO {1 | 0} (1 = on, enabled, 0 = off, disabled)
Description: Enables (1 = ON) or disables (0 = OFF) echo mode (see PAR. 8.2.2.1). When echo mode is ON
causes all subsequent characters to be echoed back. When echo mode is OFF, turns off the character
echo after the nest line terminator character. The *RST command has no effect on echo status
B.85 SYSTem:COMMunication:SERial:ECHO? QUERY
SYST:COMM:SER:ECHO?
[STANDARD MODELS ONLY]\
Syntax:
Short Form: SYST:COMM:SER:ECHO?
Long Form: SYSTem:COMMunication:SERial:ECHO?
Return Value:
H
= on, enabled or 00
H
= off, disabled)
Description: Indicates whether echo mode is on (01
H
) or off (00
H
). (See PAR. 8.2.2.1.)
B.86 SYSTem:COMMunication:SERial:ENABle COMMAND
SYST:COMM:SER:ENAB
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:ENAB {1 | 0} (1 = on, enabled, 0 = off, disabled)
Long Form: SYSTem:COMMunication:SERial:ENAB {1 | 0} (1 = on, enabled, 0 = off, disabled)
Description: Enables (1 = ON) or disables (0 = OFF) transmission of data via the RS 232 port (see PAR. 8.2.2)
Once RS 232 transmission has been disabled, it can be enabled again by either turning the unit off,
then on, or by sending SYST:COMM:SER:ENAB 1 via the GPIB port.
B.87 SYSTem:COMMunication:SERial:ENABle? QUERY
SYST:COMM:SER:ENAB?
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:ENAB?
Long Form: SYSTem:COMMunication:SERial:ENAB?
Return Value:
H
= on, enabled or 00
H
= off, disabled)
Description: Indicates whether RS 232 transmission mode is enabled (01
H
= ON) or disabled (00
H
= OFF).
(See PAR. 8.2.2.)
B.88
SYST
em:COMMunication:SERial:PACE COMMAND
SYST:COMM:SER:PACE
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:PACE {NONE | XON}
Long Form: SYSTem:COMMunication:SERial:PACE {NONE | XON}
Description: Enables (XON) or disables (NONE) data flow control via the serial interface (see PAR. 8.2.2.3)
B.89 SYSTem:COMMunication:SERial:PACE? QUERY
SYST:COMM:SER:PACE?
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:PACE?
Long Form: SYSTem:COMMunication:SERial:PACE?
Return Value:
H
= on, XON enabled or 00
H
= off, XON disabled or NONE)
Description: Identifies whether data flow control via the serial interface is enabled (01
H
= XON) or disabled
(00
H
= NONE) (see PAR. 8.2.2.3).
B.90
SYST
em:COMMunication:SERial:PROMpt COMMAND
SYST:COMM:SER:PROM
[STANDARD MODELS ONLY]
Syntax:
Short Form: SYST:COMM:SER:PROM {1 | 0} (1 = on, enabled, 0 = off, disabled)
Long Form: SYSTem:COMMunication:SERial:PROMpt {1 | 0} (1 = on, enabled, 0 = off, disabled)
Description: Enables (1 = ON) or disables (0 = OFF) prompt (see PAR. 8.2.2.2). When prompt is ON, causes the
unit to return > character after the command is parsed.