4-2
KLP-DEV 031113
KepcoDCPWR Reset
Sends *RST to Power supply, set output off, volt=0, curr min, over voltage and over
current to max values
KepcoDCPWR Reset with Defaults
Supplied for compatibility purposes uses above
KepcoDCPWR Self-test
Sends *TST? To unit and returns result- o= all okay.
Output Control functions
KepcoDCPWR Configure Voltage Level
Set voltage output setting to a specific value
KepcoDCPWR Configure Current Level
Sets current output setting to a specific level
KepcoDCPWR Query Voltage Level
Queries unit and returns voltage level setting
KepcoDCPWR Query Current Level
Queries unit and returns Current level setting
KepcoDCPWR Configure Voltage Limit
Set virtual voltage setting to a specific value
KepcoDCPWR Configure Current Limit
Sets virtual current setting to a specific level
KepcoDCPWR Query Voltage Limit
Queries unit and returns virtual model voltage level setting
KepcoDCPWR Query Current Limit
Queries unit and returns virtual model Current setting
KepcoDCPWR Configure OVP
Set over voltage setting to a specific value
KepcoDCPWR Configure OCP
Sets Over current setting to a specific level
KepcoDCPWR Configure Output State
Sets output on or off
KepcoDCPWR Query Output State
Returns Output on(1) or off(0).
Measurement
KepcoDCPWR Measure [MSR]
Returns the voltage read back 9 default or Current read back value from KLP.
List Functions
KepcoDCPWR Configure Current Mode
Sets unit to List or Fixed mode of operation. Fixed operation is default
KepcoDCPWR Configure Voltage Mode
Sets unit to List or Fixed mode of operation. Fixed operation is default
KepcoDCPWR Configure User
Sequence
Initializes list from an array of either voltage and dwell or Current and dwell to execute
the list a number of times.
KepcoDCPWR Clear All Lists
Clears the list if not executing.
KepcoDCPWR Configure List
Loads a specific list from an array of numbers.
KepcoDCPWR Configure List Count
Initializes the list count variable
Trigger Functions
KepcoDCPWR Configure Triggered
Current Level
Establishes the current level upon receipt of a valid trigger
KepcoDCPWR Configure Triggered
Voltage Level
Establishes the voltage level upon receipt of a valid trigger
KepcoDCPWR Configure Triggered
Source
Establishes the source for a trigger and arms the trigger system.
KepcoDCPWR initiate[TRG]
Issue a software trigger to the KLP.
KepcoDCPWR Abort [TRG]
Clears the trigger system.
Error and status reporting
KepcoDCPWR Error-Query
Provides entry from the error queue of the power supply.
TABLE 4-1. KLP LABVIEW G DRIVER FUNCTIONS (CONTINUED)