beautypg.com

Security level, Restart, Data security – TA Triumph-Adler P-C3060 MFP User Manual

Page 277

background image

8-33

Setup and Registration (System Menu) > System Menu

Security Level

[System Menu/Counter] key > [] [] key > [System/Network] > [OK] key > [] [] key > [Security Level] > [OK] key

Restart

[System Menu/Counter] key > [] [] key > [System/Network] > [OK] key > [] [] key > [Restart] > [OK] key

Data Security

[System Menu/Counter] key > [] [] key > [System/Network] > [OK] key > [] [] key > [Data Security] > [OK] key

Configure settings for data stored in the optional SSD and machine's memory.

Item

Description

Security Level

Specify the security level.

Value

Low:

This mode is used during maintenance. Do not use normally.

High:

This is the security setting we recommend. Use this setting normally.

Very High: In addition to [High] setting, this setting disables the machine settings to be

changed from external command.

Item

Description

Restart

Restart the CPU without turning the power switch off. Use this to deal with any unstable
operation by the machine. (Same as the computer restart.)

Item

Description

SSD Initializ.

Initialize data saved on an optional SSD.

Data Security Kit (E) Operation Guide

NOTE

This function is displayed when the optional SSD is installed and the optional Data Security Kit
is activated.

DataSanitization

Return the following information registered in the machine to the factory defaults.

Address Book

System settings

Fax transmission and reception / forwarding data

Transmission histories

Data saved in Custom Box

Optional applications

IMPORTANT

Data saved in an application or SD card cannot be erased. To erase data on an SD card,
you must format the SD card.

Format SD Card (page 8-16)

NOTE

Once in progress, the processing cannot canceled.
Before executing this function, disconnect modular, network, and other cables.
Do not turn off the main power switch while sanitizing the data. If the main power is turned off
during data erasing, erasing will be executed automatically when the power is restored,
however, complete erasure cannot be guaranteed.

This manual is related to the following products: