Chapter 2 Front Panel Operation

RIGOL

User’s Guide for DSA800 Series

2-21

Table 2-11 Edit menus of amplitude correction

Menu

Explanation

Point

Create or edit the data point of a correction factor.
Range: 1 to 200

Frequency

Set the frequency of the specified point in the correction
factor.

Amplitude

Set the amplitude correction of the specified point in the
correction factor.
Range: -120 dB to 100 dB

Del Point

Delete the specified point data in the correction factor:
frequency and amplitude correction.

4. Freq Interp

Set the interpolation type of the points between two points in the correction
table during amplitude correction.

 In Lin mode, the frequency and amplitude use a Lin and Log unit to

perform interpolation respectively.

 In Log mode, both of the parameters use a Log unit.


5. Delete

Clear all the frequency and amplitude correction data of the selected
correction factor.

6. Corr Table

Turn on the correction table to view the correction data edited. At this
moment, the screen is divided into two parts with the upper showing the
measurement curve and the lower showing the points edited, frequency and
amplitude.

7. Corr View

 All: view the data of all the correction factors.
 Sel: view the data of the selected correction factor.





This manual is related to the following products: