To Edit the Timer Parameters Manually

You need to set P groups (No.0 to No.(P-1)) of timer parameters; wherein, P is the

number of output groups currently set. Only 6 groups of parameters can be
displayed on each page of the timer parameter list and you can press

or

to

view and set the parameters of the other groups. This interface provides timer

parameter preview; users can view the values on the current page of the timer

parameter list (the horizontal axis represents time and the vertical axis represents

voltage and current).

1. Press Parameter and use the numeric keyboard, the left/right direction key or

the knob to select the specified number (No.) in the timer parameter list.

2. Use the up/down direction key to select the voltage (V), current (C) and time (s)

of the current group respectively and use the numeric keyboard or the left/right

direction key and knob to input the desired value.

3. Use the same method to set the parameters of the other groups.

To Edit the Timer Parameters using Templet

The instrument provides various built-in output templets. Users can select the

desired templet, edit the timer parameters using the templet and create waveform.

The instrument will output according to the waveform currently created.

Press Templet to open the templet editing menu. You can edit the timer parameters

according to the steps below.

1. Select the editing object

2. Select the templet

3. Edit the timer parameters

4. Construct the output waveform

1. Select the editing object

Press Edit Obj to select "Voltage" or "Current".
 Voltage: when it is selected, the interface displays the voltage preview and

you can set all the groups to output a fixed current. Press Current and use

the numeric keyboard or the left/right direction key and knob to set the

current value.

 Current: when it is selected, the interface displays the current preview and

you can set all the groups to output a fixed voltage. Press Voltage and use

the numeric keyboard or the left/right direction key and knob to set the

voltage value.

2. Select the templet

Press Type to select the desired templet, including Sine, Pulse, Ramp, Stair Up,

Stair Dn, StairUpDn, Exp Rise and Exp Fall.