RIGOL

Chapter 2 Front Panel Operations

2-54

DP800 User’s Guide

VISA descriptor is the resource name and describes the accurate name and

location of the VISA resource. If the LAN interface is currently used to

communicate with the instrument, the VISA descriptor is

TCPIP::172.16.3.100::INSTR.

5. Set the IP Address

Please acquire a valid IP address from your network administrator firstly and set

the IP address manually in manual IP configuration mode. The format of the IP

address is nnn.nnn.nnn.nnn; wherein, the first nnn ranges from 1 to 223

(except 127) and the other three range from 0 to 255.

Press IP Addr and use the numeric keyboard and left/right direction key or the

knob and left/right direction key to input the desired IP address. This setting is

stored in the non-volatile memory and the instrument will load the IP address

set automatically at the next power-on if DHCP and Auto IP are set to "Off".

6. Set the Subnet Mask

Please acquire a valid subnet mask from your network administrator firstly and

set the subnet mask manually in manual IP configuration mode. The format of

the subnet mask is nnn.nnn.nnn.nnn; wherein, the range of nnn is from 0 to

255.

Press Sub Mask and use the numeric keyboard and left/right direction key or

the knob and left/right direction key to input the desired subnet mask. This

setting is stored in the non-volatile memory and the instrument will load the

subnet mask set automatically at the next power-on if DHCP and Auto IP are

set to "Off".

7. Set the Gateway

Please acquire a valid gateway address from your network administrator firstly

and set the gateway manually in manual IP configuration mode. The format of

the gateway is nnn.nnn.nnn.nnn; wherein, the first nnn ranges from 1 to 223

(except 127) and the other three range from 0 to 255.

Press Gateway and use the numeric keyboard and left/right direction key or the

knob and left/right direction key to input the desired gateway address. This

setting is stored in the non-volatile memory and the instrument will load the

gateway address set automatically at the next power-on if DHCP and Auto IP

are set to "Off".

8. Set the DNS Server

Please acquire a valid DNS server address from your network administrator

firstly and set the DNS (Domain Name Service) address manually in manual IP

configuration mode. The format of the DNS address is nnn.nnn.nnn.nnn;

wherein, the first nnn ranges from 1 to 223 (except 127) and the other three

range from 0 to 255.