RIGOL DP832 User Manual
Page 139
RIGOL
DP800 User’s Guide
5-3
OVP/OCP
Accuracy ±(Output Percentage+Offset)
0.5%+0.5V/0.5%+0.5A
Voltage Programming Control Speed (1% within the total variation range)
Channel
Rise
Fall
Full Load
No Load
Full Load
No Load
DP832
CH1
CH2
CH3
<50ms
<50ms
<15ms
<33ms
<38ms
<14ms
<46ms
<46ms
<24ms
<400ms
<400ms
<100ms
DP831
CH1
CH2
CH3
<18ms
<33ms
<35ms
<17ms
<36ms
<42ms
<20ms
<44ms
<45ms
<200ms
<400ms
<400ms
DP821
CH1
CH2
<110ms
<15ms
<30ms
<15ms
<110ms
<20ms
<800ms
<400ms
DP811
CH1
<45ms
<42ms
<51ms
<1089ms
Temperature Coefficient per ℃ (Output Percentage+Offset)
Channel
Voltage
Current
DP832
CH1
CH2
CH3
0.01%+5mV
0.01%+5mV
0.01%+2mV
0.01%+2mA
0.01%+2mA
0.01%+2mA
DP831
CH1
CH2
CH3
0.01%+2mV
0.01%+2mV
0.01%+2mV
0.02%+3mA
0.02%+3mA
0.02%+3mA
DP821
CH1
CH2
0.01%+3mV
0.01%+3mV
0.02%+3mA
0.02%+3mA
DP811
CH1
0.01%+3mV
0.02%+3mA
Stability
[3]
±(Output Percentage+Offset)
Channel
Voltage
Current
DP832
CH1
CH2
CH3
0.02%+2mV
0.02%+2mV
0.01%+1mV
0.05%+2mA
0.05%+2mA
0.05%+2mA
DP831
CH1
CH2
CH3
0.03%+1mV
0.02%+2mV
0.02%+2mV
0.1%+3mA
0.05%+1mA
0.05%+1mA
DP821
CH1
CH2
0.02%+1mV
0.02%+1mV
0.1%+1mA
0.1%+1mA
DP811
CH1
0.02%+1mV
0.1%+1mA