Timer and delayer, Timer and delayer -15 – RIGOL DP832 User Manual
Page 65
Chapter 2 Front Panel Operations
RIGOL
DP800 User’s Guide
2-15
Timer and Delayer
DP800 provides the timer and delayer functions.
When the timer is enabled, the instrument outputs the preset voltage and current
values (at most 2048 groups). Users can set the number of output groups of the
timer as well as the voltage, current and timing time of each group. Besides, the
instrument provides various built-in output templets and users can select and edit
the templet as well as create timer parameters based on the templet. The instrument
will output according to the parameters currently created.
When the delayer is enabled, the instrument enables or disables the output
according to the preset state and delay time (at most 2048 groups). Users can set
the number of output groups of the delayer as well as the state and delay time of
each group.
Users can store the edited timer parameters (timer file, with the suffix "*.RTF") and
delayer parameters (delay file, with the suffix "*.RDF") in internal or external
memory and recall them when required.
Press Timer (the backlight turns on) to open the timer and delayer interface (as
shown in Figure 2-1). The function of each menu key is as follows.
1. Timer Set: open the timer parameter setting interface and set the timer
parameters;
2. Timer: turn on or off the timer;
3. Delay Set: open the delayer parameter setting interface and set the delayer
parameters;
4. Delayer: turn on or off the delayer.
Figure 2-1 Timer and Delayer Interface