Trigger output – RIGOL DP832A User Manual
Page 94
RIGOL
Chapter 2 Front Panel Operations
2-40
DP800A User’s Guide
or “Output Toggle”.
Output On: when the trigger condition is met, turn on the output of the
channel currently selected as the source under control.
Output Off: when the trigger condition is met, turn off the output of the
channel currently selected as the source under control.
Output Toggle: when the trigger condition is met, turn the waveform of the
channel currently selected as the source under control upside down and
then output the waveform.
5. Sensitivity
Press Sensitivity to set the trigger sensitivity to low, middle or high. Selecting
relatively lower trigger sensitivity can avoid mis-trigger at the noise.
6. Enable
Press Enable to enable or disable the trigger input function of the
corresponding data line.
Trigger Output
When the output of the specified control source meets the trigger condition, the
specified data line outputs level or square waveform according to the setting of the
output signal.
Press
Trigger Trig to select “Out” and the trigger output setting
interface is opened, as shown in the figure below.
Figure 2-7 Trigger Output Setting Interface
1. Data Line
Press Data Line to select D0, D1, D2 or D3 and the data line currently selected
will be highlighted on the screen. Users can set the trigger conditions of the four
data lines respectively.
2. Control Source
Press Ctrl Src to select any of CH1, CH2 and CH3 as the control source.