RIGOL DP832A User Manual
Page 65
Chapter 2 Front Panel Operations
RIGOL
DP800A User’s Guide
2-11
the two channels can be set.
You can perform the following operations according to your need.
1. Only enable the track function of a single channel and track the
voltage setting value
The operation procedures are as follows (in this example, only the track function
of CH2 of DP831A is enabled).
Select the “Independent” tracking mode
Press Utility System Track Set Track to select “Independent”.
Enable the track function of CH2
Select CH2 and press Track to select “On”. At this point, the track function
of CH2 is enabled and the tracking status icon
is displayed in the CH2
area in the user interface.
Disable the track function of CH3 (ignore this step if the track function of
CH3 is currently disabled)
Select CH3 and press Track to select “Off”. At this point, the track function
of CH3 is disabled and the tracking status icon
in the CH3 area in the
user interface disappears.
Track the voltage setting value
Select CH2, press Voltage and set the desired voltage. At this point, the
voltage of CH3 changes accordingly. For example, set the voltage of CH2 to
+5V; the voltage of CH3 will change to -5V automatically.
Note: At this point, the voltage setting value of CH3 cannot be set and can
only change with that of CH2.
2. Enable the track functions of both of the two channels and track the
voltage setting value
First, you can enable the track functions of the two channels (take DP831A as an
example) using any of the following methods.
Method 1
Select the “Synchronous” tracking mode
Press Utility System Track Set Track to select “Synchronous”.
Tip
The track function only tracks the voltage setting value and the actual output
voltage will not be affected.