Low power modes, Expansion port pin out – Remote Processing RPC-210 User Manual
Page 53
EXPANSION PORT & POWER
BASIC
SECTION 12
Page 12-2
No heat sink is necessar y if power( P (MAX ) ) is less
than 1. 7W and the board operate s at 25°C. A roug h rule
of thumb is you can draw 100 mA @5V from the board
and not require a heat sink.
Ther e is a small he at sink on the RP C-210. U19 is
screwed to the board to get slightly better heat
dissipation. However, if you are going to operate the
heat sink at high temperatures (> 80°C) for extended
periods of time, it is advisable to add a heat sink.
If you expect to operate the bo ard at high tempe ratures,
use the following formula to determine maximum power
dissipation:
P(MA X) = 125 - T
A
----------
60
W h e re : T
A
is ambient temperature.
Use a heat sink for a TO-220 IC. Suggested heat sink
types from Aavid are:
A a vi d P / N
Height
P(max) @
50 °C
P(max)
@ 5 0°C
577002B00000
0.25"
2.85
2.14
577102B00000
0.375
3.46
2.63
577202B00000
0.500
3.64
2.73
Other heat sink types and styles may be used depending
upon your mounting c onsidera tions. Heat dissipa tion is
greatly increased with air flow around the regulator.
Be sure to use silicone grease to increase heat flow. An
insulator is no rma lly not necessar y unless you w ant to
keep the heat sink from shorting to an external case.
You may need to bend up U19 to attach the heat sink.
LOW POWER MODES
Low power modes are discussed in SECTION 7, REAL
TIME CLOC K, L OW P OWE R MO DES.
Expansion Port Pin Out
J8 Pin
Description
1
Data bus 0 line
2
External I/O select
3
Data bus 1 line
4
External power. Same as P1-E
5
Data bus 2 line
6
Interrupt 0
7
Data bus 3 line
8
Reset (active low)
9
Data bus 4 line
10
+ 5V power
11
Data bus 5 line
12
Ground
13
Data bus 6 line
14
Ground
15
Data bus 7 line
16
Address line A4
17
Address line A0
18
+ 5V power
19
Address line A1
20
Address line A5
21
Address line A2
22
No connection
23
Address line A3
24
ALE line
25
RD line (active low)
26
WR line (active low)