beautypg.com

1 prosys installer menu options, Report codes, Utility outputs – RISCO Group Upload/Download software User Manual

Page 35: User codes, Wl button

background image

Chapter 5:  Main Menu Bar Options 

 

Page 32

5.3.1 ProSYS Installer Menu Options

Reporting 
Codes:
 

For setting the Reporting codes in the system to the 
Monitoring station. 

Special 
Reporting 
Codes:
 

For setting the Special Reporting codes in the 
system. The 2 hex digits are converted to 3 decimal 
digits (For use with ADEMCO Contact ID and SIA 
as additional codes to the built in conversion table 
of the panel 

Auto SIA Codes: The Auto SIA codes option is accessed. 

When this option is selected a message box opens asking you if 
you are sure that you want to send Auto SIA Codes Yes/No?  If 
you do, click Yes.  A new message box opens showing Auto SIA 
Codes command sent successfully. 
 
Note:

 

It is recommended to perform Reset Codes before 

performing Auto SIA Codes
 
Note:  
It is important to complete the panel configuration before 
sending the Auto SIA Codes command. Selecting Auto SIA ID 
codes sends a command to the panel to set all report codes 
according to the panel configuration. 
Warning: Report codes are not updated automatically in the 
software.  To update, select Upload all It is important to complete 

the panel configuration before sending the Auto SIA Codes

Auto contact ID 
codes:
 

The Auto SIA codes option is accessed.  

 
When this option is selected a message box opens asking you if 
you are sure that you want to send Auto Contact ID Codes 
Yes/No?  
If you do, click Yes.  A new message box opens showing 
Auto Contact ID Codes command sent successfully.

  

 
Note:

 

It is recommended to perform Reset Codes before 

performing Auto contact ID codes
 
Note
: It is important to complete the panel configuration before 
sending the Auto Contact ID Codes command. Selecting Auto 
Contact ID 
codes sends a command to the panel to set all report 
codes according to the panel configuration. 
Warning: Report codes are not updated automatically in the 
software.  To update – do Upload all It is important to complete 
the panel configuration before sending the Auto Contact ID 
command.

 

06. Report Codes 

For setting the reporting 
codes in the system, from 
the main menu select 
Installer>Report Codes 
and one of these options: 

 
Note
: Most Report Codes have a 
corresponding Restore Code which, 
following a reported event, restores 
the settings to normal. These Codes 
are 2‐character codes. The numbers 
00 appear as the default in the cell 
fields of the codes. To set them, 
type 2 characters from 0 to 9 and/or 
from A to F.  The codes you type 
replace the default in the cell field.

 

Reset Codes: 

For resetting all the reporting codes for the 
Monitoring station. 

7. Utility Outputs

 

For setting the Utility outputs in the system, from the main menu 
select Installer>Utility Outputs. 

8. User Codes

 

For setting the User codes in the system, from the main menu select 
Installer>User Codes. 

9. WL Button 

For setting the WL button parameters in the system, from the main 
menu select Installer>WL Button.