Display Maximum, Minimum, and Input Current

The maximum and minimum values and the measured input loop current may be
displayed temporarily on the lower display. To display these values, press the
DISPLAY

button. The meter will display the word MAXIMUM on the bottom display and

the maximum value reached (since the last maximum reset) on the top display. Press
the DISPLAY button again and the meter will display the word MINIMUM on the
bottom display and the minimum value reached on the top display. Pressing the
RESET

button while either of these values is displayed will reset that value to the

current display value.

Press the DISPLAY button a third time and the meter will display LOOP MA on the
bottom display and the measured input current in milliamps (mA) on the top display.
The current display will remain for 10 seconds and then the lower display will return
to normal run mode as programmed in Configuring the Display (DISPLAY) on page
26. Press the DISPLAY button a fourth time to return to the normal operation. The
meter will display RESUME followed by the run mode lower display.