beautypg.com

Precision Digital PD6800 User Manual

Page 19

background image

PD6800-0L1 Loop-Powered Process Meter

Instruction Manual

19

Menu Button

 Press the Menu button to enter Programming Mode.
 Press the Menu button during Programming Mode to return to the previous

menu selections.

 Hold the Menu button for 1.5 seconds at any time to exit Programming Mode

and return to Run Mode.

 Press and hold the Menu button for 3 seconds to access the Advanced Fea-

tures

of the meter.

Right / Reset Button

 Press the Right arrow button to reset the maximum or minimum value while it

is being displayed (see Up / Display Button below).

 Press the Right arrow button to move to the next digit or decimal position

during programming.

 Press Right to go backward through most selection menus.

Up / Display Button

 Press Display when in Run Mode to cycle through displaying the maximum

value, minimum value, and the loop input value in mA. The display will time
out in 12 seconds. Press Display again to resume normal lower display oper-
ation (lower display will read RESUME).

 Press the Up arrow button to scroll forward through the menus, decimal point,

or to increment the value of a digit.

Enter

Button

 Press the Enter button to access a menu or to accept a setting.
 Press Enter to acknowledge alarm (if enabled).

This manual is related to the following products: