4-15

IN1404XT Video Scaler and Switcher • Programmer’s Guide

Command/Response Table for RS-232 Commands (Cont’d)

Command

ASCII Command

Response

Additional description

(host to scaler)

(scaler to host)

Input mode (continued)

Set input mode to user defined

[ST 2]

[OK]

All input sampling rates have the
same user-definable settings.
However, the inputs are
restricted to values that are close
to the sampling rate detected. If
a full range of values is
necessary, the user-defined mode
can be manually selected.

Input mode (continued)

If the auto-detect mode cannot determine the input sampling rate, the user-
defined mode is selected automatically.

Redetect the input mode

[ST 3]

{none}

Allows users to initiate a new
detection sequence and reload
the input/output settings

View scan type

value

[ST?]

[

X35

]