beautypg.com

Programmer’s guide, cont’d – Extron electronic IN1404XT User Manual

Page 70

background image

Programmer’s Guide, cont’d

IN1404XT Video Scaler and Switcher • Programmer’s Guide

4-14

Command/Response Table for RS-232 Commands (Cont’d)

Command

ASCII Command

Response

Additional description

(host to scaler)

(scaler to host)

Blanking (continued)

Set

H blanking value to default

[BH@]

[OK]

Reset the horizontal blanking
setting to its factory default (9).

View

the H blanking value

[BH?]

[

X31

]

Show the horizontal blanking
setting.

Set

a specific V blanking value

[BV

X32

]

[OK]

Specify the vertical blanking
adjustment.

Increment V blanking

value

[BV+]

[OK]

Increase the vertical blanking
setting by one.

Decrement V blanking

value

[BV-]

[OK]

Decrease the vertical blanking
setting by one.

Set

V blanking value to default

[BV@]

[OK]

Reset the vertical blanking
setting to its factory default (9).

View

the V blanking value

[BV?]

[

X32

]

Show the vertical blanking
setting.

Total pixels

The total pixels and active pixels adjustments are interactive. Setting one of
these variables may require adjusting the other.

Set

a specific total pixel value

[TP

X33

]

[OK]

Specify the total pixels
adjustment.

Increment total pixels

value

[TP+]

[OK]

Increase the total pixels setting
by one.

Decrement total pixels

value

[TP-]

[OK]

Decrease the total pixels setting
by one.

Set

total pixels value to default

[TP@]

[OK]

Reset the total pixels setting to its
factory default (9).

View

the total pixels value

[TP?]

[

X33

]

Show the total pixels setting.

Scan type

1

.

The scan type settings are available for RGBHV, RGBS, RGsB, and
progressive component video inputs only.

2

.

Three scan type options are available; one, two, or all three can be turned
on simultaneously.

Toggle

interlaced on or off

[ST 0]

[OK]

Toggle the interlaced function on
or off.

Toggle swapped fields

on or off

[ST 1]

[OK]

Toggle the swapped fields
function on or off.

Toggle invert sync

on or off

[ST 2]

[OK]

Toggle the inverted sync function
on or off.

View scan type

value

[ST?]

[

X34

]

View scan type settings.

Input mode

The input mode settings are available for RGBHV, RGBS, RGsB, and
progressive component video inputs only.

Set input mode to autodetect

[ST 0]

[OK]

Allows the scaler to automatically
detect new input sampling rates
and adjust itself accordingly.

Set input mode to lockout changes [ST 1]

[OK]

Prevents the scaler from
switching back and forth
between input sampling rates.