Programmer’s guide, cont’d – Extron electronic IN1404XT User Manual
Page 70
Programmer’s Guide, cont’d
IN1404XT Video Scaler and Switcher • Programmer’s Guide
4-14
Command/Response Table for RS-232 Commands (Cont’d)
Command
ASCII Command
Response
Additional description
(host to scaler)
(scaler to host)
Blanking (continued)
Set
H blanking value to default
[BH@]
[OK]
Reset the horizontal blanking
setting to its factory default (9).
View
the H blanking value
[BH?]
[
X31
]
Show the horizontal blanking
setting.
Set
a specific V blanking value
[BV
X32
]
[OK]
Specify the vertical blanking
adjustment.
Increment V blanking
value
[BV+]
[OK]
Increase the vertical blanking
setting by one.
Decrement V blanking
value
[BV-]
[OK]
Decrease the vertical blanking
setting by one.
Set
V blanking value to default
[BV@]
[OK]
Reset the vertical blanking
setting to its factory default (9).
View
the V blanking value
[BV?]
[
X32
]
Show the vertical blanking
setting.
Total pixels
The total pixels and active pixels adjustments are interactive. Setting one of
these variables may require adjusting the other.
Set
a specific total pixel value
[TP
X33
]
[OK]
Specify the total pixels
adjustment.
Increment total pixels
value
[TP+]
[OK]
Increase the total pixels setting
by one.
Decrement total pixels
value
[TP-]
[OK]
Decrease the total pixels setting
by one.
Set
total pixels value to default
[TP@]
[OK]
Reset the total pixels setting to its
factory default (9).
View
the total pixels value
[TP?]
[
X33
]
Show the total pixels setting.
Scan type
1
.
The scan type settings are available for RGBHV, RGBS, RGsB, and
progressive component video inputs only.
2
.
Three scan type options are available; one, two, or all three can be turned
on simultaneously.
Toggle
interlaced on or off
[ST 0]
[OK]
Toggle the interlaced function on
or off.
Toggle swapped fields
on or off
[ST 1]
[OK]
Toggle the swapped fields
function on or off.
Toggle invert sync
on or off
[ST 2]
[OK]
Toggle the inverted sync function
on or off.
View scan type
value
[ST?]
[
X34
]
View scan type settings.
Input mode
The input mode settings are available for RGBHV, RGBS, RGsB, and
progressive component video inputs only.
Set input mode to autodetect
[ST 0]
[OK]
Allows the scaler to automatically
detect new input sampling rates
and adjust itself accordingly.
Set input mode to lockout changes [ST 1]
[OK]
Prevents the scaler from
switching back and forth
between input sampling rates.