Extron electronic IN1404XT User Manual
Page 53
3-33
IN1404XT Video Scaler and Switcher • Operation
Problem
Possible cause
Solution
The image is cropped
Input horizontal
Select Input>Advanced>
on the right.
blanking may be set too H. Blanking and increase the
low.
setting to match the input signal.
Horizontal position
Reduce the horizontal position
may be set too far to
setting.
the right.
Display may be set
Use the blue screen and the
incorrectly.
display’s position or size controls
to fit the image on the display.
The image is cropped
Input vertical blanking Select Input>Advanced>
on the top.
may be set too high.
V. Blanking and reduce the setting
to match the input signal.
Vertical position may
Increase the vertical position
be set too far to the top. setting.
Display may be set
Use the blue screen and the
incorrectly.
display’s position or size controls
to fit the image on the display.
The image is cropped
Input vertical blanking Select Input>Advanced>
on the bottom.
may be set too low.
V. Blanking and increase the
setting to match the input signal.
Vertical position may
Reduce the vertical position
be set too far to the
setting.
bottom.
Display may be set
Use the blue screen and the
incorrectly.
display’s position or size controls
to fit the image on the display.
Double image.
Multiple formats
Ensure only one signal is
connected to a single
connected to each input.
input.
(Interlaced component
Select Input>Advanced>Scan Type
and RGB video)
Even
and then select Invert Sync.
and odd fields
improperly detected.
Black & white image
Signal format
Select Input>Signal Format and
only.
incorrect.
ensure that signal format selected
matches the signal input.
Hooking along the
Horizontal tracking
Select Input>Horiz Tracking and
top of the image.
too slow.
increase the tracking speed.
(RGBS and RGsB
Select Output>Sync Format and
video)
Incorrect
select pulses on (A) if off (B) or
serration pulses status. turn pulses off if on.
Frozen image.
Freeze is activated.
Press freeze to deactivate the
feature.
Displayed image is
Input aspect ratio
Select Input>Aspect Ratio and
the wrong shape.
incorrect.
select the correct aspect ratio.
Output aspect ratio
Select Output>Resolution and
incorrect.
select a resolution to match the
display.