Appendix A - Optional Equipment and Accessories

37

Smart Battery Combiner

The Smart Battery Combiner (ME-SBC

TM

) is designed to monitor and

charge a second battery using a portion of the current that is charging
the main battery. The ME-SBC eliminates a signifi cant voltage drop,
and provides automatic turn-on and turn-off based on adjustable
voltage set-points. This allows different batteries to be charged from
a single charging source, and prevents overcharging/undercharging.

Standard Remote Control

The ME-RC50 Remote Control Panel is simple to use; an LCD screen
and “at a glance” LEDs display complete inverter/charger status. Soft
keys provide simple access to menus and a rotary encoder knob al-
lows you to scroll through and select a wide range of settings.

Auto Generator Start Controller

The ME-AGS-N Automatic Generator Start controller (Network ver-
sion) is designed to automatically start your generator based on low
battery condition or high temperature. It works

with 12, 24, and

48-volt battery banks and includes a 4-position DIP (Dual In-line
Package) switch which provides the ability to change the relay timing
confi gurations to allow compatibility with a wider range of generators.

Battery Monitor Kit

The ME-BMK Battery Monitor Kit is a single battery bank amp-hour
meter

that monitors the condition of the battery and provides infor-

mation to let you know how much energy you have available and
let you plan your electrical usage to ensure the battery is not being
over-discharged. The ME-BMK-NS version does not include

a DC

shunt – order the ME-BMK to receive a 500A/50mv DC shunt.

Fuse Block/Fuses

The Magnum Fuse/Fuse-blocks are used to protect the battery bank,
inverter, and cables from damage caused by DC short circuits and
overloads. They include a slow-blow fuse with mounting block and
protective cover. The 125 and 200 amp models use an ANL type fuse
and the 300 and 400 amp models use a Class-T fuse.

DC Load Disconnect

The MM-DCLD (DC Load Disconnect) pigtail adapter is designed to
provide a means to DISABLE the inverter function when a 12-volt
DC signal is removed.

Ignition Switch Activate

The MM-ISA (Ignition Switch Activate) is a pigtail adapter is designed
to automatically ENABLE the inverter function when a 12-volt DC
signal is supplied.

Appendix A - Optional Equipment and Accessories

The following Magnum Energy components are available for use
with the MMS-E Series inverter/charger. Some of these items are
required depending upon the intended use of the inverter.