Figure 1-2, Top and Left Side Features

4

Positive DC Terminal (red) - the inverter’s connection to
the positive terminal on the battery bank.

5

Input Circuit Breaker - this circuit breaker protects the
unit’s internal wiring and pass-thru relay.

6

Output Circuit Breaker - this circuit breaker provides
another layer of overload protection. This is not a branch
circuit-rated breaker. Separate AC output breakers may be
required on the output.

7

Mounting Flanges (x4) - secures the inverter to shelf/
wall.

8

AC Wiring Compartment - provides access for all AC input
and output connections on the inverter.

9

AC Output Connection - AC knockout for hardwiring AC
output.

10

AC Input Connection - a strain relief clamp for hardwiring
AC input.

11

DC Ground Terminal - this connection is used to tie the
exposed chassis of the inverter to the DC grounding system.
This terminal accepts CU/AL conductors from 2.08 mm² to
13.29 mm² (#14 AWG to #6 AWG).