Powador-proLOG XL
Analogue inputs
Number of
1
1
4
DC voltage measurement [V]
0 to 10 (max. 24)
0 to 10 (max. 24)
0 to 10 (max. 24)
DC current measurement [mA]
0 to 20 (max. 40/3 V)
0 to 20 (max. 40/3 V)
0 to 20 (max. 40/3 V)
Resistance measurement
PT1000
PT1000
PT1000
Measuring accuracy
1% of the end value
(0.1 V/0.2 mA)
1% of the end value
(0.1 V/0.2 mA)
1% of the end value
(0.1 V/0.2 mA)
Digital inputs
Number of
1
1
4
S0 pulse input (DC) [V]
Low: 0 to 7
High: 9 to 24
Low: 0 to 7
High: 9 to 24
Low: 0 to 7
High: 9 to 24
–
Powered exclusively by the unit’s internal power supply
–
Can be confi gured as a status input
–
Potential-free contacts
–
S0 interface specifi cation conforms to DIN 43864
Digital output
Number of
1
1
1
S0 optocoupler (DC)
Max. 70 V/50 mA
Max. 70 V/50 mA
Max. 70 V/50 mA
Display elements
4 LEDs
4 LEDs
4 LEDs
Interfaces
–
Can be confi gured as an alarm or pulse output
–
Observe the polarity
Communication
Ethernet
100 MBit (RJ45)
100 MBit (RJ45)
100 MBit (RJ45)
Analogue modem (PSTN)*
1 (RJ12)
-
1 (RJ12)
ISDN modem*
-
-
1 (RJ12)
GSM/GPRS modem
-
-
SIM card slot
Antenna (FME)