beautypg.com

KACO Powador-proLOG User Manual

Page 32

background image

Operating Instructions Powador-proLOG_EN

Page 33

S e c t i o n 8 ·

M e n u D e s c r i p t i o n

8.2.2 Current

sensors

If current sensors (Powador-go) are connected, the current
measured values of the current sensors are shown here.

8.2.3 Inverter

overview

If inverters are connected and properly addressed, current
and accumulated measured values are shown here. Total
yields are displayed in the “Total for all inverters” section.
The “Overview of individual inverters”) section lists all con-
nected inverters, including address, unit status, current feed-
in power and daily yield that was reached at the time of the
query. Each inverter address is linked to the inverter details.

8.2.4 Inverter

details

This section shows all of the inverter’s measured values. You
can only select one inverter at a time from the drop-down list.

8.3 Status

8.3.1 System

messages

This menu item provides an overview of the possible alarm
statuses.

The measured value alarms result from the criteria speci-
fi ed in “Admin monitoring -> Formulas -> Criteria 0-4”. The
status overview lists the following information:

Designation:

The name that was defi ned in Formula -> Criterion”) is

shown

here.

Status:

Indicates whether the criterion is defi ned as active

or

inactive.

Upper limit:

This shows the current upper limit value for the

monitoring

criterion.

Actual value:

This shows the current actual value for the monitoring

criterion.

Lower limit:

This shows the current lower limit value for the

monitoring

criterion.

Alarm counter:

This shows how often the criterion exceeded a

limit

value.

Sending status:

Indicates whether there are currently alarm messages

that are waiting to be sent.

Information:

This shows when the last alarm occurred.

The system alarms relate to messages that are based
on faults in the monitoring system.

Designation:

The reason for the error message is shown here.

Alarm type:

Information about the type of e-mail/fax alarm

message.

Alarm destination:

Shows which contact the error message was sent to.

Alarm counter:

This shows how often the alarm was tripped.

Sending status:

Indicates whether there are currently alarm messages

that are waiting to be sent.

Info Information:

This shows when the last alarm occurred.

The Sending status of e-mails status shows the sys-
tem’s current status. For example, if e-mails are waiting to be
sent, “busy” is shown in the “sendstate” fi eld. The normal
status is “Ready to Send”.

This manual is related to the following products: