5 emc installation conditions, 1 sgdv-****05* (analog pulse model), 1 sgdv-05 (analog pulse model) – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual
Page 60

2 Installation
2.5.1 SGDV-05 (Analog Pulse Model)
2-38
2.5
EMC Installation Conditions
This section describes the recommended installation conditions that satisfy EMC
guidelines for each model of the SGDV SERVOPACK. The conditions required for
the standard type (base-mounted) of SERVOPACK are described. Refer to this sec-
tion for other SERVOPACK models such as the rack-mounted types as well.
This section describes the EMC installation conditions satisfied in test conditions
prepared by Yaskawa. The actual EMC level may differ depending on the actual sys-
tem’s configuration, wiring, and other conditions. However, because this product is
built-in, check that the following conditions are still met after being installed in the
user’s product.
The applicable standards are EN55011 group 1 class A, EN61800-3, and
EN61000-6-2.
2.5.1 SGDV-05 (Analog Pulse Model)
Single-phase 100 V, SGDV-F05A ( = R70, R90, 2R1,
2R8)
Symbol
Cable Name
Specification
I/O signal cable
Shield cable
Cable for safety unit
Shield cable
Linear servomotor main circuit cable
Shield cable
Linear scale connection cables
Shield cable
Main circuit cable
Shield cable
Power supply:
Single-phase
100 VAC
U, V, W
L1, L2
L1C, L2C
CN2
CN1
Shield box
SERVOPACK
PE
PE
Linear
scale
Linear
servomotor
1
3
4
5
Clamp
Noise
filter
Clamp
Clamp
Clamp
CN8
2
Surge
absorber
Two turn
One turn
Core
Core
Core
Core
Core
Core
Two turn
Two turn
Clamp
Host
controller
Safety unit
One turn