2 servopack installation environment – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual
Page 25
2.1 Installation Environment and Applicable Standards
2-3
2
Installation
Impact Resistance: The linear servomotor will with stand the following
impact acceleration.
Installation site: An environment that satisfies the following conditions
• Indoors and free of corrosive or explosive gases
• Well-ventilated and free of dust and moisture
• Facilitates inspection and cleaning
• Free of high magnetic field
2.1.2 SERVOPACK Installation Environment
Surrounding air temperature: 0
°C to 55°C
Ambient humidity: 90% RH or less (with no condensation)
Altitude: 1,000 m or less
Vibration resistance: 4.9 m/s
2
Shock resistance: 19.6 m/s
2
Withstand voltage Voltage: 1,500 Vrms/m AC
Frequency: 50 or 60 Hz
Installation Precautions
• Mounting in a Control Panel
To prevent the temperature around the SERVOPACK from exceeding 55
°C, take into
account the size of the control panel, the layout of the SERVOPACK, and the cooling
method. For details, refer to 2.4 SERVOPACK Installation.
• Mounting Near a Heating Unit
To prevent the temperature around the SERVOPACK from exceeding 55
°C, suppress
radiant heat from the heating unit and temperature rise due to convection.
Servomotor model
Impact acceleration
SGLGW
SGLFW
SGLTW
196 m/s
2
× twice
SGLC
98 m/s
2
× twice